Hydrogels hold several key advantages that make them beneficial in Microfluidics experiments. They allow diffusion of small molecules such as nutrients and growth factors required for cell culture as well as waste removal. The optical transparency of the hydrogels enables the real-time microscopy of the samples. Moreover, hydrogels are biocompatible. They are non-toxic to cells and have an adjustable Young modulus that can be tailored to mimic the condition of the cells’ actual extracellular matrix (ECM).
The first thing that should be considered in working with hydrogels is the crosslinking method in the microfluidic device. Depending on the application, the crosslinking approach can differ. Of note, when cells are involved more delicate materials and crosslinking should be chosen. The properties of the hydrogel matrix will depend on the polymer chains, crosslinking method, and the crosslinking density.
The high water content of hydrogels makes them prone to swelling and shrinking. The degree of crosslinking has a direct effect on the swelling and shrinking of the hydrogels. The type of media can also influence the hydrogels. A hydrogel that swells in one media can shrink in another. In general, the hydrogels with higher degrees of crosslinking undergo less shrinking and swelling.
The porosity of the hydrogels determines how freely the cells have access to nutrients and waste removal. In hydrogels with high porosity, cells have better access to nutrients. But, chances of false results are also higher in drug permeability tests since the molecules can get absorbed in the matrix. On the other hand, in low porosity hydrogels, it is more difficult for cells to have access to nutrients but the likelihood of false signals is lower.
This mode of crosslinking takes advantage of the attraction of charged molecules via electrostatic interactions. Examples of reversible crosslinking include crosslinking of collagen, matrigel®, and alginate by changing pH, temperature, or ionic interactions. One drawback of this type of crosslinking is the low resolution. They cannot be fabricated with high resolution due to the difficulties in local changing of pH or temperature and limitations of diffusion-based crosslinking. However, these features make these hydrogels suitable for sacrificial molding.
Covalent bonds between the molecules can cause more permanent crosslinking. A typical way of crosslinking is adding functional groups that will undergo reactions in the presence of an external trigger such as light or heat. Acrylates, acrylamides, Hyaluronic acid (HA), chitosan, dextran, gelatin, poly(ethylene glycol)(peg) are examples of hydrogels crosslinked by covalent radicals.
Although, not as popular as common elastomers such as PDMS or thermoplastics like PMMA, hydrogels are also candidates for microfabrication. Some of the methods that have been used for microfabrication of hydrogels include:
-UV lithography
Lithographic methods are widely used for fabrication of microfluidic device. It can also be modified to be used for hydrogel crosslinking. A UV light source and a mask are needed in this method. The mask should be placed between the hydrogel and the light source. The UV light passes through the mask and crosslinks the hydrogel and defines the features. A well-known technique uses this approach to produce custom-made hydrogel microparticles. The hydrogel precursor solution passes through a microfluidic channel where it gets exposed to UV to form the microparticles. Then solidified particles get flushed out of the device inside the collection chamber to allow for the next round of crosslinking.
-Stereolithography
Here, a UV light source is combined with an automated stage to print the hydrogels in 3D and crosslink them in real-time. This method can be easily used to make 3D scaffolds for cell culture. Although this technique can be simply automated, it has not been promising for manufacturing hydrogel microfluidic chips yet.
-Two-photon polymerization
Two-photon polymerization (2PP) utilizes a femtosecond laser and a precise stage to generate sub-micron features in photosensitive material. The laser pulse is close to the Infrared spectrum which makes it cell friendly as opposed to UV light. Also, with the 2PP method, free-hanging objects can be made without the need for any support. Although 2PP is capable of fabricating features with ultrahigh resolutions, its drawbacks such as costly equipment and time-consuming fabrication hinder its widespread use.
-Soft lithography (microcontact printing or molding)
Soft lithography refers to a series of techniques used for replicating or fabricating a structure using an elastomeric stamp or mold. A more detailed explanation of the soft lithography technique for fabricating microfluidic chips can be found here.
Microcontact printing includes inking and drying of the target solution over the surface of a stamp followed by placing the stamp in contact with the hydrogel to print the patterns on its surface. The hydrogel could be cast over the stamp (called the master mold here) to replicate its features onto the hydrogel. The hydrogel chip can then be peeled off after crosslinking. Alternatively, the mold could be made of a sacrificial material to be dissolved after the fabrication. Original uFluidix post.